Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
PLoS One ; 19(3): e0299402, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38512845

RESUMEN

Recent advances in gene editing are enabling the engineering of cells with an unprecedented level of scale. To capitalize on this opportunity, new methods are needed to accelerate the different steps required to manufacture and handle engineered cells. Here, we describe the development of an integrated software and hardware platform to automate Fluorescence-Activated Cell Sorting (FACS), a central step for the selection of cells displaying desired molecular attributes. Sorting large numbers of samples is laborious, and, to date, no automated system exists to sequentially manage FACS samples, likely owing to the need to tailor sorting conditions ("gating") to each individual sample. Our platform is built around a commercial instrument and integrates the handling and transfer of samples to and from the instrument, autonomous control of the instrument's software, and the algorithmic generation of sorting gates, resulting in walkaway functionality. Automation eliminates operator errors, standardizes gating conditions by eliminating operator-to-operator variations, and reduces hands-on labor by 93%. Moreover, our strategy for automating the operation of a commercial instrument control software in the absence of an Application Program Interface (API) exemplifies a universal solution for other instruments that lack an API. Our software and hardware designs are fully open-source and include step-by-step build documentation to contribute to a growing open ecosystem of tools for high-throughput cell biology.


Asunto(s)
Programas Informáticos , Automatización , Citometría de Flujo/métodos
2.
PLoS One ; 19(2): e0297879, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38394072

RESUMEN

Liquid chromatography purification of multiple recombinant proteins, in parallel, could catalyze research and discovery if the processes are fast and approach the robustness of traditional, "one-protein-at-a-time" purification. Here, we report an automated, four channel chromatography platform that we have designed and validated for parallelized protein purification at milligram scales. The device can purify up to four proteins (each with its own single column), has inputs for up to eight buffers or solvents that can be directed to any of the four columns via a network of software-driven valves, and includes an automated fraction collector with ten positions for 1.5 or 5.0 mL collection tubes and four positions for 50 mL collection tubes for each column output. The control software can be accessed either via Python scripting, giving users full access to all steps of the purification process, or via a simple-to-navigate touch screen graphical user interface that does not require knowledge of the command line or any programming language. Using our instrument, we report milligram-scale, parallelized, single-column purification of a panel of mammalian cell expressed coronavirus (SARS-CoV-2, HCoV-229E, HCoV-OC43, HCoV-229E) trimeric Spike and monomeric Receptor Binding Domain (RBD) antigens, and monoclonal antibodies targeting SARS-CoV-2 Spike (S) and Influenza Hemagglutinin (HA). We include a detailed hardware build guide, and have made the controlling software open source, to allow others to build and customize their own protein purifier systems.


Asunto(s)
Coronavirus Humano 229E , Coronavirus Humano OC43 , Animales , SARS-CoV-2 , Proteínas Recombinantes/metabolismo , Programas Informáticos , Lenguajes de Programación , Glicoproteína de la Espiga del Coronavirus/metabolismo , Mamíferos
3.
bioRxiv ; 2024 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-38370663

RESUMEN

Organoids are powerful models of tissue physiology, yet their applications remain limited due to a lack of complex tissue morphology and high organoid-to-organoid structural variability. To address these limitations we developed a soft, composite yield-stress extracellular matrix that supports freeform 3D bioprinting of cell slurries at tissue-like densities. Combined with a custom piezoelectric printhead, this platform allows more reproducible and complex morphogenesis from uniform and spatially organized organoid "seeds." At 4 °C the material exhibits reversible yield-stress behavior to support long printing times without compromising cell viability. When transferred to cell culture at 37 °C, the material cross-links and exhibits similar viscoelasticity and plasticity to basement membrane extracts such as Matrigel. We use this setup for high-throughput generation of intestinal and salivary gland organoid arrays that are morphologically indistinguishable from those grown in pure Matrigel, but exhibit dramatically improved homogeneity in organoid size, shape, maturation time, and budding efficiency. The reproducibility of organoid structure afforded by this approach increases the sensitivity of assays by orders of magnitude, requiring less input material and reducing analysis times. The flexibility of this approach additionally enabled the fabrication of perfusable intestinal organoid tubes. Combined, these advances lay the foundation for the efficient design of complex tissue morphologies in both space and time.

4.
PLOS Glob Public Health ; 4(2): e0002766, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38381748

RESUMEN

Luminescence is ubiquitous in biology research and medicine. Conceptually simple, the detection of luminescence nonetheless faces technical challenges because relevant signals can exhibit exceptionally low radiant power densities. Although low light detection is well-established in centralized laboratory settings, the cost, size, and environmental requirements of high-performance benchtop luminometers are not compatible with geographically-distributed global health studies or resource-constrained settings. Here we present the design and application of a ~$700 US handheld, battery-powered luminometer with performance on par with high-end benchtop instruments. By pairing robust and inexpensive Silicon Photomultiplier (SiPM) sensors with a low-profile shutter system, our design compensates for sensor non-idealities and thermal drift, achieving a limit of detection of 1.6E-19 moles of firefly luciferase. Using these devices, we performed two pilot cross-sectional serology studies to assess sars-cov-2 antibody levels: a cohort in the United States, as well as a field study in Bangladesh. Results from both studies were consistent with previous work and demonstrate the device's suitability for distributed applications in global health.

5.
Nat Methods ; 19(4): 461-469, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35314838

RESUMEN

The promise of single-objective light-sheet microscopy is to combine the convenience of standard single-objective microscopes with the speed, coverage, resolution and gentleness of light-sheet microscopes. We present DaXi, a single-objective light-sheet microscope design based on oblique plane illumination that achieves: (1) a wider field of view and high-resolution imaging via a custom remote focusing objective; (2) fast volumetric imaging over larger volumes without compromising image quality or necessitating tiled acquisition; (3) fuller image coverage for large samples via multi-view imaging and (4) higher throughput multi-well imaging via remote coverslip placement. Our instrument achieves a resolution of 450 nm laterally and 2 µm axially over an imaging volume of 3,000 × 800 × 300 µm. We demonstrate the speed, field of view, resolution and versatility of our instrument by imaging various systems, including Drosophila egg chamber development, zebrafish whole-brain activity and zebrafish embryonic development - up to nine embryos at a time.


Asunto(s)
Encéfalo , Pez Cebra , Animales , Encéfalo/diagnóstico por imagen , Drosophila , Desarrollo Embrionario , Microscopía Fluorescente/métodos
6.
Science ; 375(6585): eabi6983, 2022 03 11.
Artículo en Inglés | MEDLINE | ID: mdl-35271311

RESUMEN

Elucidating the wiring diagram of the human cell is a central goal of the postgenomic era. We combined genome engineering, confocal live-cell imaging, mass spectrometry, and data science to systematically map the localization and interactions of human proteins. Our approach provides a data-driven description of the molecular and spatial networks that organize the proteome. Unsupervised clustering of these networks delineates functional communities that facilitate biological discovery. We found that remarkably precise functional information can be derived from protein localization patterns, which often contain enough information to identify molecular interactions, and that RNA binding proteins form a specific subgroup defined by unique interaction and localization properties. Paired with a fully interactive website (opencell.czbiohub.org), our work constitutes a resource for the quantitative cartography of human cellular organization.


Asunto(s)
Mapeo de Interacción de Proteínas , Proteínas/metabolismo , Proteoma/metabolismo , Proteómica/métodos , Sistemas CRISPR-Cas , Análisis por Conglomerados , Conjuntos de Datos como Asunto , Colorantes Fluorescentes , Células HEK293 , Humanos , Inmunoprecipitación , Aprendizaje Automático , Espectrometría de Masas , Microscopía Confocal , Proteínas de Unión al ARN/metabolismo , Análisis Espacial
7.
PLoS Comput Biol ; 17(8): e1009257, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34370724

RESUMEN

Manual microscopic inspection of fixed and stained blood smears has remained the gold standard for Plasmodium parasitemia analysis for over a century. Unfortunately, smear preparation consumes time and reagents, while manual microscopy is skill-dependent and labor-intensive. Here, we demonstrate that deep learning enables both life stage classification and accurate parasitemia quantification of ordinary brightfield microscopy images of live, unstained red blood cells. We tested our method using both a standard light microscope equipped with visible and near-ultraviolet (UV) illumination, and a custom-built microscope employing deep-UV illumination. While using deep-UV light achieved an overall four-category classification of Plasmodium falciparum blood stages of greater than 99% and a recall of 89.8% for ring-stage parasites, imaging with near-UV light on a standard microscope resulted in 96.8% overall accuracy and over 90% recall for ring-stage parasites. Both imaging systems were tested extrinsically by parasitemia titration, revealing superior performance over manually-scored Giemsa-stained smears, and a limit of detection below 0.1%. Our results establish that label-free parasitemia analysis of live cells is possible in a biomedical laboratory setting without the need for complex optical instrumentation. We anticipate future extensions of this work could enable label-free clinical diagnostic measurements, one day eliminating the need for conventional blood smear analysis.


Asunto(s)
Malaria Falciparum/parasitología , Parasitemia/diagnóstico , Parasitemia/parasitología , Plasmodium falciparum/clasificación , Plasmodium falciparum/citología , Biología Computacional , Aprendizaje Profundo , Diagnóstico por Computador , Eritrocitos/parasitología , Humanos , Interpretación de Imagen Asistida por Computador , Malaria Falciparum/diagnóstico por imagen , Microscopía Ultravioleta/instrumentación , Microscopía Ultravioleta/métodos , Redes Neurales de la Computación , Parasitemia/diagnóstico por imagen , Plasmodium falciparum/crecimiento & desarrollo
8.
PLoS Comput Biol ; 17(8): e1009274, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34370726

RESUMEN

Recent advancements in in situ methods, such as multiplexed in situ RNA hybridization and in situ RNA sequencing, have deepened our understanding of the way biological processes are spatially organized in tissues. Automated image processing and spot-calling algorithms for analyzing in situ transcriptomics images have many parameters which need to be tuned for optimal detection. Having ground truth datasets (images where there is very high confidence on the accuracy of the detected spots) is essential for evaluating these algorithms and tuning their parameters. We present a first-in-kind open-source toolkit and framework for in situ transcriptomics image analysis that incorporates crowdsourced annotations, alongside expert annotations, as a source of ground truth for the analysis of in situ transcriptomics images. The kit includes tools for preparing images for crowdsourcing annotation to optimize crowdsourced workers' ability to annotate these images reliably, performing quality control (QC) on worker annotations, extracting candidate parameters for spot-calling algorithms from sample images, tuning parameters for spot-calling algorithms, and evaluating spot-calling algorithms and worker performance. These tools are wrapped in a modular pipeline with a flexible structure that allows users to take advantage of crowdsourced annotations from any source of their choice. We tested the pipeline using real and synthetic in situ transcriptomics images and annotations from the Amazon Mechanical Turk system obtained via Quanti.us. Using real images from in situ experiments and simulated images produced by one of the tools in the kit, we studied worker sensitivity to spot characteristics and established rules for annotation QC. We explored and demonstrated the use of ground truth generated in this way for validating spot-calling algorithms and tuning their parameters, and confirmed that consensus crowdsourced annotations are a viable substitute for expert-generated ground truth for these purposes.


Asunto(s)
Colaboración de las Masas/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Transcriptoma , Automatización , Hibridación in Situ , ARN/química , Análisis de Secuencia de ARN/métodos , Flujo de Trabajo
9.
Cell ; 182(5): 1232-1251.e22, 2020 09 03.
Artículo en Inglés | MEDLINE | ID: mdl-32822576

RESUMEN

Lung cancer, the leading cause of cancer mortality, exhibits heterogeneity that enables adaptability, limits therapeutic success, and remains incompletely understood. Single-cell RNA sequencing (scRNA-seq) of metastatic lung cancer was performed using 49 clinical biopsies obtained from 30 patients before and during targeted therapy. Over 20,000 cancer and tumor microenvironment (TME) single-cell profiles exposed a rich and dynamic tumor ecosystem. scRNA-seq of cancer cells illuminated targetable oncogenes beyond those detected clinically. Cancer cells surviving therapy as residual disease (RD) expressed an alveolar-regenerative cell signature suggesting a therapy-induced primitive cell-state transition, whereas those present at on-therapy progressive disease (PD) upregulated kynurenine, plasminogen, and gap-junction pathways. Active T-lymphocytes and decreased macrophages were present at RD and immunosuppressive cell states characterized PD. Biological features revealed by scRNA-seq were biomarkers of clinical outcomes in independent cohorts. This study highlights how therapy-induced adaptation of the multi-cellular ecosystem of metastatic cancer shapes clinical outcomes.


Asunto(s)
Neoplasias Pulmonares/genética , Biomarcadores de Tumor/genética , Línea Celular , Ecosistema , Humanos , Neoplasias Pulmonares/patología , Macrófagos/patología , Análisis de Secuencia de ARN/métodos , Análisis de la Célula Individual/métodos , Linfocitos T/patología , Microambiente Tumoral/genética
10.
HardwareX ; 3: 117-134, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30221210

RESUMEN

Microfluidic technologies have been used across diverse disciplines (e.g. high-throughput biological measurement, fluid physics, laboratory fluid manipulation) but widespread adoption has been limited in part due to the lack of openly disseminated resources that enable non-specialist labs to make and operate their own devices. Here, we report the open-source build of a pneumatic setup capable of operating both single and multilayer (Quake-style) microfluidic devices with programmable scripting automation. This setup can operate both simple and complex devices with 48 device valve control inputs and 18 sample inputs, with modular design for easy expansion, at a fraction of the cost of similar commercial solutions. We present a detailed step-by-step guide to building the pneumatic instrumentation, as well as instructions for custom device operation using our software, Geppetto, through an easy-to-use GUI for live on-chip valve actuation and a scripting system for experiment automation. We show robust valve actuation with near real-time software feedback and demonstrate use of the setup for high-throughput biochemical measurements on-chip. This open-source setup will enable specialists and novices alike to run microfluidic devices easily in their own laboratories.

11.
Biosens Bioelectron ; 63: 218-231, 2015 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-25105943

RESUMEN

Culture of cells using various microfluidic devices is becoming more common within experimental cell biology. At the same time, a technological radiation of microfluidic cell culture device designs is currently in progress. Ultimately, the utility of microfluidic cell culture will be determined by its capacity to permit new insights into cellular function. Especially insights that would otherwise be difficult or impossible to obtain with macroscopic cell culture in traditional polystyrene dishes, flasks or well-plates. Many decades of heuristic optimization have gone into perfecting conventional cell culture devices and protocols. In comparison, even for the most commonly used microfluidic cell culture devices, such as those fabricated from polydimethylsiloxane (PDMS), collective understanding of the differences in cellular behavior between microfluidic and macroscopic culture is still developing. Moving in vitro culture from macroscopic culture to PDMS based devices can come with unforeseen challenges. Changes in device material, surface coating, cell number per unit surface area or per unit media volume may all affect the outcome of otherwise standard protocols. In this review, we outline some of the advantages and challenges that may accompany a transition from macroscopic to microfluidic cell culture. We focus on decisive factors that distinguish macroscopic from microfluidic cell culture to encourage a reconsideration of how macroscopic cell culture principles might apply to microfluidic cell culture.


Asunto(s)
Técnicas de Cultivo Celular por Lotes/instrumentación , Materiales Biocompatibles/química , Dimetilpolisiloxanos/química , Técnicas Analíticas Microfluídicas/instrumentación , Animales , Células Cultivadas , Diseño de Equipo , Análisis de Falla de Equipo , Humanos
12.
Nat Protoc ; 9(7): 1713-26, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24967621

RESUMEN

Time-dependent analysis of dynamic processes in single live cells is a revolutionary technique for the quantitative studies of signaling networks. Here we describe an experimental pipeline and associated protocol that incorporate microfluidic cell culture, precise stimulation of cells with signaling molecules or drugs, live-cell microscopy, computerized cell tracking, on-chip staining of key proteins and subsequent retrieval of cells for high-throughput gene expression analysis using microfluidic quantitative PCR (qPCR). Compared with traditional culture dish approaches, this pipeline enhances experimental precision and throughput by orders of magnitude and introduces much-desired new capabilities in cell and fluid handling, thus representing a major step forward in dynamic single-cell analysis. A combination of microfluidic membrane valves, automation and a streamlined protocol now enables a single researcher to generate 1 million data points on single-cell protein localization within 1 week, in various cell types and densities, under 48 predesigned experimental conditions selected from different signaling molecules or drugs, their doses, timings and combinations.


Asunto(s)
Técnicas Analíticas Microfluídicas , Transducción de Señal , Animales , Técnicas de Cultivo de Célula , Línea Celular , Rastreo Celular , Perfilación de la Expresión Génica , Ratones , Técnicas Analíticas Microfluídicas/instrumentación , Células 3T3 NIH , Programas Informáticos
13.
Phys Chem Chem Phys ; 15(19): 7050-4, 2013 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-23579859

RESUMEN

Energy conversion devices require the parallel functionality of a variety of components for efficient operation. We present a versatile microfluidic test-bed for facile testing of integrated catalysis and mass transport components for energy conversion via water electrolysis. This system can be readily extended to solar-fuels generators and fuel-cell devices.

14.
Anal Chem ; 85(2): 816-9, 2013 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-23252432

RESUMEN

High-throughput multiplexed proteomics of small-volume biospecimens will generate new opportunities in theranostics. Achieving parallel top-down and bottom-up mass spectrometry analyses of target proteins using a unified apparatus will improve proteome characterization. We have developed a novel silicon-based microfluidic device, multinozzle emitter array chip (MEA chip), as a new platform for small-volume proteomics using liquid chromatography-nanoelectrospray ionization mass spectrometry (LC-nanoESI-MS). We demonstrate parallel, on-chip, and online LC-MS analysis of hemoglobin and its tryptic digests directly from microliters of blood, achieving a detection limit of less than 5 red blood cells. Our MEA chip will enable clinical proteomics of small-volume samples.


Asunto(s)
Hemoglobinas/análisis , Técnicas Analíticas Microfluídicas , Proteómica , Cromatografía Liquida , Humanos , Técnicas Analíticas Microfluídicas/instrumentación , Silicio/química , Espectrometría de Masa por Ionización de Electrospray
15.
Anal Chem ; 82(21): 8954-60, 2010 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-20936785

RESUMEN

Poly(dimethyl siloxane) (PDMS)-based microfluidic devices are now commonly used for a wide variety of biological experiments, including cell culture assays. However, the porous, hydrophobic polymer matrix of PDMS rapidly absorbs small hydrophobic molecules, including hormones and most small-molecule drugs. This makes it challenging to perform experiments that require such substances in PDMS microfluidic devices. This study presents evidence that a sol-gel treatment of PDMS that fills the polymer matrix with silica nanoparticles is effective at reducing the absorption of drugs into the material while preserving its biocompatibility, transparency, and oxygen permeability. We show that the absorption of two anticancer drugs, camptothecin and a kinase inhibitor, is reduced to such an extent that on-chip microfluidic cell culture experiments can recapitulate the results obtained off-chip.


Asunto(s)
Materiales Biocompatibles/química , Técnicas de Cultivo de Célula/instrumentación , Dimetilpolisiloxanos/química , Técnicas Analíticas Microfluídicas/instrumentación , Absorción , Antineoplásicos Fitogénicos/aislamiento & purificación , Camptotecina/aislamiento & purificación , Línea Celular , Proliferación Celular , Fibroblastos/citología , Humanos , Oxígeno/química , Permeabilidad , Transición de Fase , Inhibidores de Proteínas Quinasas/aislamiento & purificación
16.
Anal Chem ; 79(22): 8557-63, 2007 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-17953452

RESUMEN

There is increasing demand for automated and quantitative cell culture technology, driven both by the intense activity in stem cell biology and by the emergence of systems biology. We built a fully automated cell culture screening system based on a microfluidic chip that creates arbitrary culture media formulations in 96 independent culture chambers and maintains cell viability for weeks. Individual culture conditions are customized in terms of cell seeding density, composition of culture medium, and feeding schedule, and each chamber is imaged with time-lapse microscopy. Using this device, we perform the first quantitative measurements of the influence of transient stimulation schedules on the proliferation, osteogenic differentiation, and motility of human primary mesenchymal stem cells.


Asunto(s)
Técnicas de Cultivo de Célula/instrumentación , Técnicas de Cultivo de Célula/métodos , Microfluídica/instrumentación , Microfluídica/métodos , Automatización , Diferenciación Celular , Movimiento Celular , Proliferación Celular , Células Cultivadas , Humanos , Células Madre Mesenquimatosas/citología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...